順泰醫療與AtCor Medical (無創中心動脈壓檢測及動脈硬化檢測的重要研發企業)強強合作,推出了這一款市場上獨家的能夠提供中心動脈壓測試的動態血壓儀。
Oscar 2 內置SphygmoCor 是現在市場上唯一能夠測試無創中心動脈壓的動態血壓監測儀,并且能夠支持藍牙數據連接。
作為擁有800多篇已發表科研文獻的無創中心動脈壓技術,SphygmoCor的加入使得順泰醫療的新一代Oscar2成為業界無創中心動脈壓的又一重磅產品。
特點
SphygmoCor 內置:全球超過800篇科研論文(包括臨床驗證內容),AtCor公司的SphygmoCor技術是無創中心動脈壓的金標準
運動容差算法減少再膨脹和錯誤讀數。動態膨脹也會縮短測量時間,并且通過控制袖帶壓力來提高病人的舒適度。
順泰醫療的專利產品Orbit系列的血壓袖帶采用了一個新穎的拉伸套設計來保持袖帶位置,同時增進病人在整個24小時研究內的舒適度。
擁有專利的次舒張期波形測量技術:能為18歲以上的患者提供一個全功能的生理波形與準確的增強指數
AccuWin Pro 4 系統軟件: 模塊化和圖形化,網絡化的新一代動態血壓縫隙軟件
臨床標準驗證:經過世界三大高血壓協會的標準驗證 BHS,ESH,AAMI
DESCRIPTION | ITEM NUMBER |
---|---|
Oscar 2? with SphygmoCor Inside | 99-0133-02 |
Micro USB Cable | 91-0130-00 |
Oscar 2 Pouch | 98-0032-07 |
Oscar 2 Belt | 98-0037-00 |
Oscar 2 User Guide | 80-0062-00 |
Oscar 2 Quick Start Guide | 82-0403-00 |
ABPM Cuff, Size 1 (18-26 cm) | 98-0239-01 |
ABPM Cuff, Size 2 (26-34 cm) | 98-0239-02 |
ABPM Cuff, Size 3 (32-44 cm) | 98-0239-03 |
ABPM Cuff, Size 4 (42-55 cm) | 98-0239-04 |
Technical Specs
SPECIFICATIONS | VALUES |
---|---|
ABPM Cuff, Size 4 (42-55 cm) | 98-0063-14 |
ABPM Cuff, Size 3 (32-44 cm) | 98-0063-13 |
ABPM Cuff, Size 4 (42-55 cm) | 98-0063-14 |
Method of Measurement | Oscillometric with step deflation |
Blood Pressure Range | Systolic: 40-260 mmHg Diastolic: 25-200 mmHg |
Heart Rate | 40-200 BPM |
Maximum | 280 mmHg |
Accuracy | Heart Rate accurate within +/-2% or +/-3 BPM, whichever is greater. Blood Pressure results meet or exceed ANSI/AAMI/ISO 81060-2:2013 standards for non-invasive accuracy: ±5 mmHg mean error & 8 mmHg standard deviation. |
Validations | Clinically validated to ESH International Protocol, BHS (A/A), and ANSI/AAMI/ISO 81060-2:2013 |
Operating Conditions | 10°C (50°F) to 50°C (122°F) 20-95% RH non-condensing |
Ingress Protection | Ordinary Equipment, No ingress protection, IPX0. |
Classification | Power: Two (2) AA batteries, continuous operation |
Data Memory | Flash memory stores up to 250 readings |
Calibration | Minimally, once every two years |
Safety Systems | Maximum inflation pressure limited to 300 mmHg; Auto safety release valve for power failure; Maximum measurement time limited to less than 140 seconds |
Sampling Periods | 24 independently programmable time periods (Time interval options: none, 5, 10, 15, 20, 30, 45, 60, 90, and 120 minutes) |
Size | Approximately 120 x 70 x 35 mm |
Weight | Approximately 275 g, including batteries |
Storage | -20° C to +70° C, 15%-95% RH non-condensing |
Data | USB 2.0 (Micro USB) with optional BluetoothTM 4.0 |
常見問題
-
我怎樣啟動/關閉裝置?
啟動時,按住啟動/停止按鈕直到您聽到連續3次快速提示音。
關閉時,按住啟動/停止按鈕直到您聽到連續5次快速提示音。
-
Oscar 2動態血壓計及其電線含有乳膠嗎?
我們的所有產品,包括Oscar 2動態血壓計、軟管和電線均不含乳膠。
-
收到錯誤提示“不能與 ABP 設備鏈接”,該如何解決?
在配置選項下選擇硬件設備,然后選擇首選。選擇一種配置進行編輯。串行端口將顯示計算機上可獲得的所有序列端口。
當使用USB適配器時,請先安裝驅動(USB 適配器包中的微型 CD)。
確保Oscar 2動態血壓計的電池有電。
確保另外的設備,如 Holter 監測儀或PDA 沒有連接到特定端口。取下設備或將Oscar 2的串行端口更換至可用端口。
確保連接了合適的ABP設備。更改設置后,連接ABP,選擇試驗端口,確保計算機和監測儀已鏈接。